Portable appliance testing (PAT) is the inspection and testing of electrical equipment that plugs into a socket. It protects staff, customers and premises from electric shock and fire, and it shows you are managing your electrical safety duties.

Is PAT testing a legal requirement?

Not as such. No law says you must "PAT test" on a set schedule. But the Electricity at Work Regulations 1989 require you to keep electrical equipment in a safe condition, and the Health and Safety at Work etc. Act 1974 requires you to look after the safety of employees and the public. The HSE says regular inspection and testing is a sensible way to do this (see its guidance HSR25 and Maintaining portable electric equipment).

In practice, that means you need to be able to show you have a system for checking equipment and keep records. PAT testing is the most common way to do that. Many insurers also expect it. Employees have a duty too: nobody should misuse electrical equipment or use it dangerously.

Private homes do not need PAT testing, although landlords must make sure any appliances they supply are safe.

How often should equipment be tested?

There is no single answer. The interval depends on a risk assessment of the equipment, how often and how roughly it is used and where. However, if you're ever in doubt, check more often. These are indicative starting points:

Equipment and settingTypical interval
Construction and building sitesAbout every 3 months
High-use or hand-held equipment, such as kettles, vacuum cleaners and power tools, or harsh settings such as commercial kitchens and workshops6 to 12 months
Offices, schools, shops and hotelsTypically every 1 to 2 years
Low-risk, rarely moved or little-used equipmentEvery 2 to 4 years, if a risk assessment supports it
New equipmentVisual check before first use; test only if in doubt

What affects how often you test

  • Type and use: items used constantly, such as kettles and vacuum cleaners, are more likely to develop faults.
  • Portability: hand-held and moved equipment is more likely to be knocked or damaged.
  • Environment: wet, dusty, hot or cold conditions, and rough use, wear equipment faster.
  • Users and age: user competence, whether equipment is used as the manufacturer intended, its age and the results of earlier tests.

An appliance that is safe today may not be in a year's time, so periodic testing matters.

What a PAT test involves

  1. Visual inspection: many faults can be seen, such as a cracked plug, frayed or damaged cable or broken casing. A visual check is the most important part of the process.
  2. Electrical tests: others only show up with a test instrument, which measures things like earth continuity and insulation.
  3. Pass or fail label: each item is marked, ideally with a dated label showing the next due date. Failed items must be repaired or taken out of use.
  4. Records: keep the certificate and test results. They show your maintenance is working and help you plan.

A competent person with the right training and calibrated equipment should do the testing and interpret the results. Staff should still be trained to look at equipment before they use it and to report anything that smokes, overheats or stops working. 

The benefits

  • Fewer accidents: testing reduces the risk of electric shock and electrical fire. If a workplace kettle is faulty and nobody has recorded it, the risk is high.
  • Legal and insurance confidence: records show that you have taken reasonable steps, which can improve how insurers see you.
  • Less downtime: faults found early do not stop work mid-task.
  • Longer equipment life: results can prompt you to move, replace or retrain, which saves money.
  • Customer trust: customers value businesses that take safety seriously.

How to spot a poor-quality PAT service

A very low price is worth questioning. A proper test takes time, and a thorough visual inspection is the most important part. When comparing quotes, ask whether:

  • plug-top covers or seals are removed so the fuse and wiring are checked
  • the correct fuse is fitted in each plug
  • detachable leads are inspected and tested separately
  • hard-wired items are inspected and tested correctly, not skipped or treated like plug-in appliances
  • each item is actually tested before it is labelled
  • the number of items quoted per day is realistic. A thorough test takes minutes, so claims of hundreds of tests a day do not add up (500 tests in a 10-hour day is one every 72 seconds)
  • engineers are employed to do a quality job rather than paid per item tested

Get PAT testing from the people who do it properly

Our qualified engineers carry out PAT testing for businesses, schools and landlords across Milton Keynes, Aylesbury, Bedford, Oxford, Luton, Northampton, Leighton Buzzard, Dunstable, Newport Pagnell and Buckingham, and give you clear, easy-to-read results. Find out about PAT testing or call 01908 564301.