Fire risk assessments for schools: what you must do and how

A school fire can injure or kill, destroy buildings and disrupt pupils' learning for months. A fire risk assessment is the legal and practical foundation for preventing that.

What the law requires

The Regulatory Reform (Fire Safety) Order 2005 requires the "responsible person" for any non-domestic premises, which includes schools, to assess the risk of fire, remove or reduce it and identify the people who are at risk. If you appoint someone to carry out an assessment, they must be a competent person with the right knowledge, understanding and training, and reviewed whenever the building or its use changes, for example after structural work. See our workplace fire risk assessment guide for how the responsible person is defined.

Why schools need to take this seriously

Insurance analysis by Zurich Municipal in 2020 found that 480 primary and secondary schools had a fire in 2019, and firefighters were called to nearly 2,000 school fires in England over three years. The causes included kitchen fires, electrical faults, malfunctioning appliances and arson. Repair bills can run into millions of pounds.

The risks are not equal across the school estate:

  • Some newer schools have sprinkler systems, but many older buildings have little active protection. Sprinklers can stop a small fire becoming a damaging one.
  • Smoke and fire alarm systems are not always adequate for the size and layout of the building, which delays warning and evacuation.
  • Beyond the risk to life, a serious fire disrupts teaching, upsets pupils and staff and can take a long time to put right.

The balancing act: likelihood and consequence

Fire risk has two parts that you weigh against each other: how likely a fire is, and how serious the consequences would be. A science lab may be less likely to have a fire than a kitchen but carry a more serious consequence if it does.

Preparing for the assessment

  1. Gather information from teachers, support staff, the site manager and, where appropriate, older pupils.
  2. Walk the whole site to add to, remove or correct that information.
  3. Work systematically. Allow enough time and divide the premises into zones.
  4. Include outdoor areas and access routes, including access for fire engines.

What to cover, area by area

AreaTypical points to look at
ClassroomsElectrical equipment and sockets, displays and furnishings, clear exits
Laboratories and workshopsChemicals, gas, heat sources, safe storage
KitchensCooking oil, appliances, extraction, suppression
Assembly hallsCapacity, exits, staging, temporary decorations
Offices and storesWaste paper, overloaded sockets, stored materials
Stairways and corridorsClear escape routes, fire doors that close and are not wedged open
OutsideBin storage, security against arson, access and assembly points

The five-step assessment

  1. Identify hazards: sources of ignition, fuel and oxygen.
  2. Identify people at risk, inside and outside the building. Highlight anyone who would be in immediate danger.
  3. Evaluate and act: assess the likelihood of a fire and the risk to people, then remove or reduce hazards. Measures include escape routes, adequate lighting, firefighting equipment, signage, alarm logbooks and properly maintained alarm systems.
  4. Record, plan, inform and train: write down significant findings and actions, and instruct and train the people who need it. Cooperate with anyone else who shares the site.
  5. Review: keep the assessment under constant review and update it when circumstances change.

Everyone on site counts

The plan must take account of pupils, staff and visitors, including disabled people and anyone with limited mobility. Consider how they will be alerted, how they will leave and what help they need. Do not forget contractors and out-of-hours users such as clubs or lettings.

Keeping it up to date

We recommend reviewing your assessment at least once a year and whenever a building changes, a department moves, new equipment arrives or a drill shows a weakness. Make sure alarms are tested and serviced, emergency lighting works and fire wardens' training is current.

Choose an experienced assessor

Given what is at stake, use an assessor with proven experience of schools. If you are unsure of your responsibilities, get in touch or call 01908 564301 and we will talk you through it.

Further reading: Fire safety risk assessment: educational premises (GOV.UK)

We carry out fire risk assessments for schools and other commercial premises across Milton Keynes, Bedford, Northampton and the surrounding areas.

Fire alarm panel and instructions mounted on a brick wall with a red emergency break glass.